Moulded
Case Circuit Breaker
1) DZ108 (3VE) series moulded case circuit breakers adopt the
advanced technology of low voltage circuit breaker from Germany ;
2) It is the replacing product of type DZ5-20, DZ5-50, and
DZ15-60 circuit breaker in the country ; 3) Rated voltage: up to
660V ; 4) Frequency: AC 40-60Hz ; 5) Rated current: 0.1-63A ; 6)
The circuit breaker does the make and break operation to the
motor, distribution wire or other electrical device in the
underload of AC3, with the protection of overload and short
circuit ; 7) Note: AC3 - The start, operation and break of
squirrel-cage asynchronous generator Mini
Circuit Breaker
Our high breaking capacity miniature breakers are used to protect
the circuit against short circuit and over load, and suitable for
distribution systems of industrial and commercial lighting and
electric machines. It has an elegant design, is lightweight and
offers reliable performance, high breaking capacity, quick
release and heat conduction installation. Its case and components
are made of high fire retardant and shock resistant plastic and
offer a long service life. It is mainly used for protection
against over-load, short-circuit and leakage in AC 50Hz,
230V/400V circuits. Meanwhile, it can also be used for
infrequently making and breaking electric appliances and lighting
circuits under normal working conditions..
Isolator
It is applied to switch on and off the circuit of the terminal
boxes or control motors, electrical apparatus, and lighting
systems. The superior thermal dynamic stability supplies more
protection to the circuits safety. Specifications: 1) Standard:
IEC 60947-3 ; 2) Rated current: 32, 63, 100A ; 3) Rated voltage:
230V / 400V ; 4) Poles:1, 2, 3, 4P ; 5) Withstand voltage: 4KV ;
6) Endurance: electrical: 1,500 times; mechanical: 8,500 times ;
7) OEM service: available
High
Breaking Capacity Mini Breaker
DZ47-63 high breaking mini breaker is applied to protect the
overload and short circuit in the lighting and motor power
distribution systems with rated frequency of AC 50Hz or 60Hz,
single-pole voltage of 240V, and max rated current of 63A. Under
normal condition, it maybe also be applied as the unfrequented
make-break electric device and lighting circuit. This product has
the following features: beautiful appearance, light in weight,
excellent and reliable function. The breaking capacity is quite
high and trips rapidly. The case body and the parts adopt the
high fire-resistant and impact plastic that can use long life.
Pole number is from 1 pole up to 4 poles.
High
Voltage Outdoor Vacuum Breaker
Model VH7 vacuum breakers are outdoor high-voltage switchgears
used in
three phase AC 50Hz electric systems with rated voltage of
40.5kV. These products feature anti-condensation, anti-fouling,
aging resistance, high temperature resistance, long service life,
and stable, reliable, maintenance free operation. This model is
primarily used for protection and control in industrial, mining
and power facilities, particularly in locations that receive
heavy use. A knob insulation method is used, employing high
performance insulating cement to seal the quenching pot in a
common porcelain bushing. The phase pole is airtight and has a
drier inside to ensure highly reliable insulation. Designed to be
used at an altitude of 2500m, it may also be used in dirty areas
of class IV. Additionally, with movement and speed able to be
effectively controlled with an omni-range buffer, the breaker and
support frame are split for greater operational performance.
Miniature
Circuit Breaker
1) Mainly applied to AC 50/60Hz circuits ; 2) With rated voltage
of 230V or less, and rated current up to 32A
Motor
Protection Circuit Breakers
1) Rated current: 25 / 40 / 63A ; 2) Rated voltage: 240 / 415V AC
; 3) Pole number: 2P, 4P ; 4) Rated operating current: 0.03 / 0.1
/ 0.3 / 0.5A Earth
Leakage Circuit Breaker
This earth leakage circuit breaker is used with circuits of 50Hz
or 60Hz with rated voltages of 240V (single-phase) and 415V (2, 3
and 4 phases) whose rated currents are up to 100A. In the event
of electric shock or excessive residual current the circuit will
be broken in 0.1 seconds, automatically protecting persons and
equipment.
Air
Circuit Breaker Series (ACB)
CDW7 multi-function circuit breakers are designed for protecting
power distribution circuits and equipment against failures such
as overload, under voltage and short-circuit.
Leakage
Breaker
This type of breaker is applicable to a line of AC 50/60Hz, rated
voltage 230V and rated current up to 32 A. It is widely used as
branch switch for overload, short circuit and leakage protection
in hotels, dwelling houses, hospitals, industrial and mining
enterprises, etc.
Automatic
Switching-Over Electrical Device
1) This electric device is applicable for a rated frequency 50Hz,
rated working voltage of 400V, and rated current of 16A-100A. 2)
In the power supply system of net-net and net-generator units
there are economical and intelligent types. This product is a PC
grade automatic switching-over electrical device that conforms to
GB/T14048.11 and IEC60947-6-1 standards. 3) Testing qualified, it
has strong environmental adaptability, high reliability, wide
working voltage range, and 75%ue-120%ue. 4)
With compact structure and small volume, which is merely 1/2 of
GB standards for the same specification. 5) The economical type
automatic switching-over electrical device uses a traditional
contactor control as a substitute for intelligent controls and is
able to automatically switch over (automatic
commissioning-automatic resetting).
Electron
Leakage Circuit Breaker
1) 230 / 400V ; 2) Pole: 2P ; 3) Quantity: 5/40
Medium
Voltage Vacuum Circuit Breaker
1) The vacuum circuit breakers use vacuum interrupters embedded
in resin poles ; 2) Embedding the interrupter in resin makes the
circuit-breaker poles particularly sturdy and protects the
interrupter against shocks, accumulation of dust and humidity ;
3) The vacuum interrupter houses the contacts and makes up the
interrupting chamber ; 4) It serves as an indoor device and
operates under the condition of rated 12/17.5KV three phase AC
voltage and 50/60Hz frequency ; 5) It can control and protect
electric devices of the industry and mine enterprises, generators
and transformer sub-station, is a perfect product for frequent
operating condition
Lightning
Arrester
1) MOA rated voltage: 24KV ; 2) MCOV: 19.5KV ; 3) 1/4μs
steep current impulse: 82KV ; 4) 8/20μs lightning current
impulse: 72KV ; 5) 30/60μs switching current impulse: 62KV ;
6) 2ms rectangular current impulse withstand: 150A ; 7) 4/10μs
high current impulse withstand: 65kA
Illuminated
Rocker Switch
1) Voltage resistance: 2000V AC, 1MIN ; 2) Operating temperature:
T85 ; 3) Operating life: more than 10,000 cycles ; 4) Contact
rating: UL, CUL - 16 /20A, 250/125V AC, 1/2HP, 125V AC; VDE---16A,
250V ; 5) Knob colors: black, red, green, orange and blue ; 6)
Base colors: gray, black and white ; 7) Switch crust dimensions:
32.2 x 16.4 x 21.8mm ; 8) Panel installation dimensions: 28.0 x
13.4mm
Hydraulic
Magnetic Mini Circuit Breaker
1) Hydraulic magnetic MCB is mainly used to protect circuit
against overload and short-circuit. 2) Adopting hydraulic
magnetic trip instead of bimetal, it has a high sensitivity, and
will not be affected by the ambient temperature. 3) They are
mainly used for illumination and distribution in industry or
domestic to protect circuit against overload and short-circuit.
4) Under the circuit of 50/60 Hz AC, 240V for one, two-pole; 415V
for three-pole, they are complying with IEC 157-1973, and BS3871.
NF
Domestic Fuse-Holder
1) STN fuse-holder for domestic protection ; 2) Rated voltage:
220V AC, rated current: up to 32A ; 3) NF standard ; 4) 10A for 8
x 23, 16A for 8 x 31, 20A for 10 x 25, 25A for 10 x 31, 32A for
10 x 38
Stannum
Jointing Thread
We offer the stannum jointing thread without plumbum to pretect
our environment, we also can supplier the thread mixed with
silver or golden, the diametre is 0.8mm;0.9mm;1.0mm;1.1mm;1.2mm
;1.5mm or others; with packing 1 KG 1 core.
Residual
Current Operated Circuit Breakers
1) Circuit: AC, 50Hz ; 2) Rated voltage: 400V ; 3) Rated current:
800A ; 4) Used for electric shock protection and indirect contact
protection
Mccb
Circuit Breaker
Ns series mould case circuit breaker is one of new type breaker
which is adopted international advanced design, manufacture
technology to develop, the rated insulating voltage is 950v.
Suitable for AC 50hz(60hz). Rated working voltage 690v or below,
rated working current is 12.5 to 630aof circuit. And use in
distributing electric energy. On-frequent making and breaking in
the normal conditions and protecting when circuit and
installation are overload. Short circuit and lacking voltage.
Rated shell-rack and the breaker which current is under 400a,
take protecting effect when mouse cage motor's non-frequent
start, breaking off working and protecting overload, short
circuit and lacking voltage.
Oil
Cup Circuit Breakers
Place of Origin: China. Circuit breakers available from 5A to
100A.
Surge
Protector (10kA)
1) Continuance voltage: ~385V ; 2) Standard discharge current:
5kA ; 3) Max. current capacity: 10kA ; 4) Protection level:
<1.8kV
AHM1L
Series Leakage Circuit Breaker AHM1L-400
It is a protective apparatus used to protect people from leakage,
mainly used in the circuit of 50Hz, rated voltage 400V, rated
current from 0 to 63A. It also can be used to distribute
electricity and protect against overload and short circuit as
well as for infrequent switchover of circuit. Specifications: 1)
AC types ; 2) Rated voltage: 400V ; 3) Rated current: 50-600A.
Two
Gang Multifunction Earth Leakage Circuit Breaker
1) Module design and standard guide installation ; 2) Current
transformer uses a beryllium membrane alloy material and has high
reliability
|