|
Fire
Extinguisher Valve
1) Mounting cup: tinplate with epoxy resin coat. 2) Actuator:
actuator with large dose. 1) Inlet thread: PZ 19.2. 2) Outlet
thread: M22x1.5. 3) Dip tube thread: M10x1. 4) Pressure: 18 -
22MPa Fiberglass
Fire Blanket
Excellent fireproof, heat resistance and insulation properties.
Effectively keep fire from outside air to put out the fire,
absorb heat to protect and save people. 1.0m x
1.0m, 1.2m x 1.2m, 1.2m x 1.8m, 1.8m x 1.8m.
Fire
Alarm Button
Faceplate: mirror finished stainless steel, titanium finished
stainless steel, hairline finished stainless steel. Fixing the
faceplate with ornamental nail. Prevents fire under
fire-emergency just by breaking glass. Switch box and turning on
the fire-switch
Heat
Detector
1) Models: 2-wire, 4-wire. 2) Advanced detection and
discrimination algorithms. 3) Easy installation and maintenance.
4) Polished low-profile housing design. 5) Durable sensor head,
no need for replacement. 6) SMD circuit board design:
satisfactory quality and reliability guaranteed. 7) N/C (normal /
close) and N/O (normal / open) relay output ways for option. 8)
AR (auto reset) function for security systems (optional for
4-wire models). 9) Five-year warranty
PVC
Water Hose
1) In accordance with the national level of GB9476-88. 2) Made
from pure polyester gauze: a) High intensity ; b) Strong pulling
force ; c) Good pressure resistance ; d) Convenient installation
and long life span. 3) Applications: constitution, anti-drought,
anti-water logging, irrigation. 4) PVC water hoses available: a)
Sizes from 1 - 8 inches ; b) Working pressure from 2 bar - 10 bar
(0.2mpc - 1.0mpc) ; c) Colors and length according to customers'
requests.
Fire
Extinguisher
fire extinguisher takes the new high-tech product E-500
extinguishing, a king of water-foam, as its material. This
product has so much characters as easy to use, non-burn and
non-explode, safe and reliably for carrying and storing. It's
suitable for car, home, office, camping, oil station, gas
station, and factory, etc. 1. Using on spot fires of class A, B,
C, D, and E, no burn again after fire-stop. 2. Environmentally
safe, contains no materials of HCFCs and HBFCs that destroy the
atmospheric ozonosphere. 3. Non-toxic, non-corrosive,
non-pollution, 100% biodegradable. 4. Spraying in any position,
continuously or intermittently
Chubb
Portable Fire Fighting Pump
CHUBB PORTABLE FIRE FIGHTING PUMP: Foam Inducted High Pressure
Air-Cooled Diesel. Ruggerini MD-151-1.16 HP 12V/24V Electric
starter motor. FE-HV Mark 2 Pump. Bell Reel SS cast hose. FD/25
Diffuser nozzle. Ray dan RTP Foam inducer. Bell glass fiberglass
foam tank x 100 ltrs. Aluminum mounting frame with forklift/crane
sling.
Fire
Hydrant and Hydrant Body
We manufacture various hydrants, hydrant components, hydrant
bodies, bonnets and O-rings from china. These products are widely
used in water supply for fire fighting. Materials are ASTM A48
CL3 and A536 85-65-7..
Fire
Escape Hood
Specifications: 1) Fire resistant and flame retardant and used to
protect against CO and toxic smoke. 2) Service life, min >
30min CO and HCN: > 30min. 3) Penetration: ≤0.01%. 4)
Leakage coefficient: ≤5%. 5) Inhalation resistance, dapa
≤80 (at 85L/min). 6) Total field of vision: 80%. 7)
Binocular field of vision: 60%. 8) Total weight: 800g
Fire
Extinguisher
Obtain the national appearance patent. Aluminium system, can't
oxidize aluminium not the whole (the red / silver / the blue) ,
hight; 275mm, diameter; 64mm, weight; 1. 0kg, dry powder is 0.
50kg. Time is 12 seconds to spray effectively maximum effective
discharge time seconds: >12 s, product weight: 2. 2lb (dry
chemical weight of 1. 0 lb, extinguisher agent charge weight 2. 2
lb) dry powder is 0. 45 & 0. 50kg (hy-3015) , body material:
steel (hy-3011~hy-3014) aluminum (hy-3015)
Smoke
Hood / Smoke Mask
The psm pocket smoke mask is a small, portable heat resistant
hood that covers the entire head to the shoulders. Protecting
eyes, nose, and mouth from lethal smoke and fumes. A special
ionized filter blocks heavy smoke and allows you to breath while
making your way to safety.
Carbon
Monoxide Alarm
1) Power: a) AC: 110 / 220V ; b) DC: 9V battery. 2) Sound level:
above 85dB (at 3m). 3) Static current: below 8μA. 4) Alarm
current: 10mA. 5) Low voltage alarm: 5.5 - 6.2V. 6) Ambient
temperature: -5 - 40°C. 7) Low battery alert: 7 - 15 days
Hydrant
Part
1) Material: cast iron, ductile iron. 2) Casting process: sand
cast, lost-form cast. 3) Surface treatment: epoxy powder
coating. 4) Product range: completed hydrants or individual
components, including hydrant bodies, bonnets, O-ring and other
components. 5) Widely used in water supply for fire fighting
Firefighting
Machine
Features: 1) Rated speed: 6,500r/min. 2) Net weight: 9.5kg. 3)
Volume wind outlet: 0.5m/s. 4) External dimensions: 1,040 x 10 x
10mm. 5) Fuel consumption volume: 2.0kg/h. Engine: 1) Model:
HL6MF-26. 2) Type: 1-cylinder, 2-stroke, air-cooled. 3)
Displacement: 78.5ml. 4) Max. power/rotation speed:
3.7/7,000kW/r/min. 5) Fuel consumption rated: 544g/kW. 6)
Carburetor: diaphragm MP22. 7) Magentor: CFW-79 CDI. 8) Spark
plug model: A4117. 9) Fuel model: RQ70. 10) Oil model: HQ-6 or
HQ-10, or L-ERB 2-stroke lubrication oil. 11) Fuel/oil mixture
ratio (based on capacity) a) First 50h: 15:1 ; b) After: 20:1.
12) Fuel tank capacity: 1,000ml
Anti-Chemical
Fire Fighting Suit
1) Material: a) Rubberized fabric ; b) Thickness: 0.45±0.05mm ;
c) Tensile strength: no less than 450N/5cm ; d) Tear strength:
not less than 32N. 2) Weight: no more than 5kg. 3) Acid
anti-permeability: under 10mm liquid pillar of 80% H2SO4,
60% HNO3 and 30% HCl for 1 hour. 4) Alkali
anti-permeability: under 10mm liquid pillar of 6.1mol/L NaOH3for
1h. 5) Benzene resistance: no cracks and not sticky after
immersing in 120# petrol for 30s. 6) Chemical anti-permeability:
5 pieces, not permeable after scouring 15min by 3L/min water
nozzles. 7) Inflammation prevention: a) Burns no longer than 2s ;
b) Inflammation prevention time: no longer than 10s. 8) Damage
period: no longer than 10cm. 9) Resistant to acid corrosion. 10)
Anti-heat: 125o x 24h. 11) Anti-coldness: a) -25o
x 5min
b) No cracks after 180º. 12) Fabric adhesion: no less than
780N/m. 13) Boots: a) Water permeation: not permeable after
immersing in water for 2
hours ; b) Bottom anti-prick: no less than 780N ; c) Bottom
electricity power isolation: no less than 5000V. 14) Used to
protect fire fighting personnel from harmful chemicals and
corrosive sunstances in a fire or accident. 15) Neither fragile
nor sticky
PVC
Fire Hose
1) Produced by new technology. 2) With high tensile strength
polyester threads used as its reinforcement. 3) With good
adaptability to cold weather conditions. 4) Light, flexible and
colored. 5) Excellent resistance to fire. 6) Working temperature:
-5~70°C. 7) Can be used as the matching hoses for winding wheels
of fire-fighting
Fire
Hydrant
Product range: completed hydrants or individual components,
including hydrant bodies, bonnets, other components. Widely used
in water supply for fire fighting
Middle
/ High Multiple Foam Generator
1) Middle / high multiple foam can full of huge area and space
quickly, changes covering type into submersed type, good fluidity
and penetrability, with high adiabatic performance, anti thermal
radiation, and thermal convection. 2) Can be the temporary refuge
for site fireman, avoids high temperature and poison smoke
Fire
Fighter Boots
1) Material: flame / heat-resistant rubber. 2) Electric shock
resistant soles and heels. 3) Steel toes with extra heavy outside
toe cap reinforcement. 4) Structural fire fighting. 5)
Slip-resistant. 6) Waterproof. 7) Application: protect feet and
legs. 8) In accordance with the Chinese Standard GA6-91
Rubber
Lined Fire Hose
1) Jacket: high tenacity polyester staples, polyester filament.
2) Easy rolling. 3) Aging resistant. 4) Size: 100mm (4"). 5)
Working pressure: 10 Bar (1.0Mpa). 6) Bursting pressure:
≥30Bar (3.0Mpa). 7) Colors of outside jacket and inner
linning: as per customers' requirements. 8) Light weight
Fire
Fighter Glove
1) Outer layer: the material is made from Nomex. It enjoys the
ability of flame resistance, oil proofness, electrical
insulation. It also has good resistance to acids and alkalis. 2)
Moisture barrier: GORE-TEX, the material could stop water passing
through to the firefighters personal clothing while allowing
perspiration and heat to escape to the outside atmosphere. 3)
Thermal barrier: it used the no-woven felt made of ARAMID. To
thermal barrier, flame resistant, anti heat radiation. 4)
Comfortable layer: flame resistant cotton. 5) Fire fighters
gloves used during structural fire fighting operations including
rescue of victim from fires, and emergency operation where sharp
or rough surface are likely to be encountered such as victim
extrications. It is certified by the Chinese Standard GA7-2004,
American standard NFPA
Smoke
Detector
Photoelectric smoke + heat alarm with 9V DC battery, ceiling type
smoke alarm with CE approval alarm. Features: Ceiling or wall
mounting. Easy to install with mounting hardware included. 9V DC
battery. Suitable for any room. Flash alarm indicator (red). Test
button for easy recommended monthly testing. Low battery signal.
Safety clip feature, not allow mounting of smoke alarm, without
battery installed. Photoelectric chamber for early detection from
all directions. Loud 85dB alarm signal. Specifications:
Power Source: 9VDC battery. Operating Current: 10uA (normal) and
20-50mA (alarm working). Sensitivity to smoke: In comply with
UL217. Sensitive to heat. BS5446: Part 1 2000. Kite mark License
no.: KM 53166. 0.81~1.42%/FT. Operating Temperature: 40 - 100°F
(4.4 - 37.8°C). Ambient Humidity: 10% - 90%. Horn Level: 85dB at
10'. Size: 110mm x 25mm. Box size: 34cmx 57cmx 42.5cm
Fireman's
Hose Nozzle
1. Virtually unbreakable - engineered from zinc, aluminum,
glass-filled nylon, and brass. 2. Adjustable from gentle shower
to powerful jet stream
FRP
Fire Extinguisher Stands
1) Skillful manufacturing. 2) Modern design. 3) Corrosion
resistance. 4) Light weight. 5) High intensity. 6) Aging
resistance. 7) Excellent dimension stability. 8) Long service
life. 9) Smooth surface. 10) Good flexibility. 11) Manufactured
using synthetic resin and reinforced with glass fiber
Fire Alarm
This smoke alarm works on the principle that infrared scatters in
the smoke to probe the smoke which is generated by the incomplete
combustion at the initial stage of the fire. The smoke alarm
consists of photoelectric system, signal processing
identification circuit and alarm circuit. The infrared scatters
on the surface of the smoke when the smoke enters the darkroom of
the detector, and then the photoelectric diode receives the
scattered light and generates the photoelectric signal current.
The photoelectric signal generates the alarm signal after being
processed by the identification circuit, accordingly the purpose
of alarming is achieved. For this smoke alarm, we promise 3 years
quality guarantee. Specifications: 1) Power supply: 9V battery.
2) Quiescent current: 6 ~ 12μA. 3) Age limit of battery: 2
years. 4) Temperature: -10°C ~ +40°C. 5) Alarm decibel:
≥85dB/cbm. 6) Sensitivity of smoke: EN14604
Stock
Tank Pressure Type Air and Foam Device
Our stock tank pressure type air and foam proportional mixing
device is composed of a foaming tank, pressure type proportional
mixer, inlet pipe, outlet pipe and control valve. When the
pressure flow goes through the proportional mixer of this device,
the water and foam can be automatically mixed according to a
certain proportion and the foam mixture will then be sent to the
foam generator and spray equipment to produce spray air foam for
fire extinguisher. This device is available in two types;
vertical and horizontal .The membranous device features a rubber
made capsule in the storage tank and the foam liquid, making it
is especially suitable for aqueous film foam liquids.
Additionally, the residue foam liquid is good for future use
after fire extinguishing. This device enjoys the advantages of
high safety, reliability and efficient fire extinguishing
performance. It is suitable use in petroleum enterprises, petrol
stations and airports.
Foam
Gun For Low Pressure And High Pressure Fire Pumps
1. Anodized light-alloy casting with rubber handle and adjusting
lever. 2. Interior parts made of stainless steel. 3. Rotating
ball-bearing type hose connector made of stainless steel.
Technical data: 1. Continuous flow-rate adjustment between 0-150
1 / min. 2. Continuous jet adjustment between full jet, flat jet
and spray jet. 3. Approx. 25m at 150 1 / min and with a 40 bar
full jet. 4. 3 / 4" BSP male threaded connector for hose
coupling. 5. Weight 3k. G. Practical advantage: 1. The ideal
equipment for combating fires inside buildings, incipient fires
and forest fires. 2. Is extremley handy in use and consumes very
little water, yet has enormous combat power and extinguishing and
cooling effectiveness. 3. Maximizes "cling-effect" of
heavy foam carpeting on vertical surfaces.
Fire-Fighting
Suit
1) Material: nomax, waterproof ventilation layer, heat insulation
layer, cosiness layer. 2) Burning resistant ability: burning
extent less than 2s. 3) Static water pressure resistance: more
than 30kPa. 4) Ventilation ability: more than 5,000gsm, 24h. 5)
TPP more than 35Cal/cm². 6) Weight: 3.5kg
Fire-Fighting
We can supply fire-fighting products including hoses, groove
couplings, fire hose nozzles, fire sprinklers and alarms, fire
hydrant, fire extinguishing etc from china.
Extinguishing
Controller
Voltage: 24/12V DC. Load current: 24V, <3A/12V, <5A.
Non-load current: 24V, <1.2A/12V, <2.5A. Moving distance of
bracing cable: 35mm. Startup time: <0.5s. Max. permitted load
(pull): 88.2N. Operating life: >100,000 times
Fire
Extinguishers
1) ABC dry powder extinguisher. 2) 1 liter, 2 liters, 3 liters, 4
liters, 6 liters, 9 liters foam and water extinguisher. 3) 1.5kg
and 6.8kg co2 extinguisher. 4) 25kg - 100kg trolley extinguisher.
5) Screen print or stick label. 6) Epoxy coated cylinder have a
phosphate under treatment to resist corrosion by paint. 7)
Auto-line control. 8) Color: RAL 3000. 9) Burst pressure: 55
bars. 10) Valve to be pressure release with CE approval. 11)
Monoammonium phosphate based dry chemical agent. 12) Capable of
fighting class A, B, C and E fires. 13) Listed dry powder
extinguisher are using 85% and 50% ABC powder and nitrogen as
propellant gas. 14) Listed cylinder with European directive
PED97/23/EC
|